Journal of Contemporary Orthodontics

Official Publication of Indian Orthodontic Society


Duraisamy, Anandan, and Patil: A spectrophotometric analysis of copper and zinc released from stainless steel brackets coated with a combination of copper oxide and zinc oxide nanoparticles in artificial saliva


Introduction

Surface coating of stainless steel brackets with nanoparticles can alter its biological and tribological properties. 1, 2, 3, 4, 5 In the recent years nano coating as a noncompliance method to reduce white spot lesions in patients undergoing fixed orthodontic treatment has received a lot of attention.6, 7, 8, 9 Nanocoating improves the antibacterial properties, prevents biofilm formation and adhesion on the surface of substrates.10, 11

Nanoparticles when used in combination may result in increased antibacterial efficacy with reduction in their individual side effects.12, 13, 14 The antibacterial effect of brackets coated with a combination of silver and zinc oxide nanoparticles against Streptococcus mutans and Lactobacillus acidophilus was greater when compared to the brackets separately coated with silver or zinc oxide. 12 Similarly the combination of copper oxide and zinc oxide demonstrated superior antibacterial effect when compared to the individual nano particles. 13 The combination also exhibited superior antibacterial effect against Streptococcus mutans when compared to silver -copper oxide and silver - zinc oxide coating on stainless steel brackets.14 Nitrogen doped titanium oxide nanocoating of stainless steel brackets demonstrated long term antimicrobial property against Streptococcus mutans. 8 Doping of titanium oxide with nitrogen narrows their photo catalytic band gap from UV spectrum to visible light, eliminating the need for UV radiation. 2

The orthodontic brackets are constantly subjected to a cyclic variation in temperature, pH and mechanical stresses from oral functions leading to bio-corrosion and leaching of metal ions into the saliva or migration into the adjacent tissues. 15, 16, 17 The biosafety of the nanoparticles used for coating the brackets is a major concern as the particles may be released from the surface coating during the prolonged orthodontic treatment. Silver ions were detected in the serum and saliva of white albino rats bonded with orthodontic brackets coated with nano silver particles. 18, 19 Presence of copper and zinc ions were observed in artificial saliva incubated at 370C with copper oxide and zinc oxide nanocoated brackets.20

The literature is replete with studies evaluating the antibacterial and frictional properties of nanocoated brackets, but only few studies have evaluated these effects clinically, because of the lack of information on their cytotoxicity and biocompatibility. 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14 The cytotoxicity of stainless steel brackets coated with the combination of copper oxide and zinc oxide nanoparticles was as low as the uncoated brackets and significantly lesser than that of brackets coated with the individual particles. 21 This reduction in cytotoxicity may be attributed to the dose dependent cytotoxic nature of copper and zinc and the reduction in quantity of the nano particles used in the combination coating.12, 21 In combination or hybrid coating, the nanoparticles are mixed in 1:1 proportion by weight reducing its quantity in the coating by half. 12, 13, 14, 21 This may reduce the levels of copper or zinc ions leaching from them when compared to the brackets coated entirely with copper oxide or zinc oxide.

To test this hypothesis, the present in vitro study was designed to evaluate and compare the levels of copper and zinc ions released into the artificial saliva from the stainless steel orthodontic brackets coated with copper oxide, zinc oxide and the combination of both particles at different time intervals.

Materials and Methods

The protocol of the current study was approved by the Institutional Review Board and Institutional Ethical Committee of SRM Dental College, Ramapuram, Chennai with an approval number of SRMDC/IRB/2023/PhD/NO.156. The sample size estimated for a power of 80 %, α error of 5 % was 15 in each group. The p value < 0.05 was considered statistically significant. Preadjusted edgewise, 0.022” slot, MBT prescription, stainless steel maxillary Ormco (ORMCO CORP, Glendora, USA) premolar brackets were used for the study.

A total number of 75 brackets were divided in three experimental groups of 20 each and one control group of 15. The study group brackets of 20 each were coated with nano particles of copper oxide, zinc oxide and a hybrid combination of both using spray pyrolysis method (Ho-TH-04, Holmark –optomechtronics Ltd, Kochi, kerala, India).20, 21 Copper oxide nanoparticles of an average size of 45 nm and zinc oxide with an average size of 40 nm with 99.9% purity was used for the nanocoating. (Ultrananotech, Bangalore, India).Scanning Electron Microscopic analysis was performed in 5 brackets randomly chosen from each group to ensure the uniformity of coating. The rest 15 brackets from each group and the 15 uncoated brackets of the control group were used for spectrophotometric analysis.

Sixty healthy human maxillary first premolar teeth, extracted for therapeutic purpose were immediately collected and store in distilled water at room temperature. Teeth with surface cracks, defects, demineralization spots, caries or restoration were not included. The crowns were amputated using a carborundum disc, the pulp chamber was cleaned and filled with a flowable composite resin. The prepared crowns were randomly grouped into 4 groups of 15 each and were bonded with the respective four groups of brackets using standard bonding protocol. 37% phosphoric acid (Anabond Eazetech Etchant Etching Gel), light cure adhesive primer and composite resin (3M Unitek Transbond XT) was used for etching and bonding.

The artificial saliva was prepared using the basic formula given by Gjerdet and Hero and later modified by Barret, Bishara and Quinn. 22, 23 The pH was adjusted to the average pH of the oral cavity (6.75) using 10M sodium hydroxide (NaOH). The four group of brackets (Group I: Copper oxide nanocoated brackets, Group II: Zinc oxide nanocoated Brackets, Group III: Copper oxide –Zinc oxide nanocoated brackets & Group 1V: Uncoated brackets )were segregated and autoclaved at 120ºC temperature 15 psi pressure for 20 minutes. The brackets were immersed into 25 ml of artificial saliva in labelled polyethylene bottles and stored at 37oC. A sample of 2ml of saliva was collected from each of the 60 bottles at the end of 24 hrs, 7th day,14th day & 28th day. After every sample collection, the artificial saliva was replaced in each bottle to avoid the cumulative effect.24

A total of 60 samples from the four groups at each time interval were collected and analysed using an atomic absorption spectrometer (GBC-932A plus GBC Scientific equipment Ltd. USA). Three plain samples of artificial saliva were used as a blind test (“0” sample) to calibrate the spectrophotometer. 24 The group I samples were analysed for the quantity of copper ions , group II for Zinc ions and group III & IV samples for both Copper & Zinc ions. The quantity of ions in ppm from each group were tabulated and subjected to statistical analysis.

One way ANOVA and Post hoc Tuckey HSD for multiple comparisons was used for between group comparisons of Copper (Group I, III & IV) and Zinc (Group II, III & IV) concentration at different time intervals (Table 1, Table 2, Table 3). Paired sample Test was used for intragroup comparison of copper and zinc ions between different time intervals (Table 4, Table 5). Independent T test was used for intergroup comparison copper and zinc ions at different time intervals (Table 6). The P value ≤ 0.05 was considered as statistically significant.

Figure 1

Mean concentration of Copper ions in ppm released from Group I (Copper oxide nanocoated brackets), Group III (Copper oxide –Zinc oxide nanocoated brackets) & Group IV (Uncoated brackets) in artificial saliva at 24 hrs, 7th day, 14th day and 28th day.

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/f2b55c06-5e8a-4bbf-b1c3-1932ddbce74cimage1.png
Figure 2

Mean concentration of Zinc ions in ppm released from Group II (Zinc oxide nanocoated brackets), Group III (Copper oxide –Zinc oxide nanocoated brackets) & Group IV (Uncoated brackets) in artificial saliva at 24 hrs, 7th day, 14th day and 28th day.

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/f2b55c06-5e8a-4bbf-b1c3-1932ddbce74cimage2.jpeg
Figure 3

Mean concentration of Copper ions in ppm released from Group I (Copper oxide nanocoated brackets) in artificial saliva at 24 hrs, 7th day, 14th day and 28th day.

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/f2b55c06-5e8a-4bbf-b1c3-1932ddbce74cimage3.png
Figure 4

Mean concentration of Zinc ions in ppm released from Group II (Zinc oxide nanocoated brackets) in artificial saliva at 24 hrs, 7th day, 14th day and 28th day.

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/f2b55c06-5e8a-4bbf-b1c3-1932ddbce74cimage4.png
Figure 5

Mean concentration of Copper and Zinc ions in ppm released from Group III (Copper oxide –Zinc oxide nanocoated brackets) in artificial saliva at 24 hrs, 7th day, 14th day and 28th day.

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/f2b55c06-5e8a-4bbf-b1c3-1932ddbce74cimage5.png
Figure 6

Mean concentration of Copper and Zinc ions in ppm released from Group IV (Uncoated brackets) in artificial saliva at 24 hrs, 7th day, 14th day and 28th day.

https://s3-us-west-2.amazonaws.com/typeset-prod-media-server/f2b55c06-5e8a-4bbf-b1c3-1932ddbce74cimage6.png
Table 1

Mean concentration of copper (from Group I, III & IV brackets) and Zinc ions ((from Group II, III & IV brackets) in ppm.(Group I: Copper oxide anno coated brackets, Group II: Zinc oxide nanocoated Brackets, Group III: Copper oxide –Zinc oxide nanocoated brackets & Group 1V: Uncoated brackets)

At 24 hrs

7th day

14 th day

28th day

Group I (Concentration of Copper in ppm)

0.0160 ± 0.0238

0.3557 ± 0.0476

0.2368   ± 0.0301

0.1336 ± 0.0172

Group II (Concentration of zinc in ppm)

0.0125 ± 0.0073

3.0935 ± 0.3916

0.8904 ± 0.1012

0.7635   ± 0.1169

Group III (Concentration of Copper in ppm)

0.0029   ± 0.0039

0.2028 ± 0.0869

0.1147 ± 0.0289

0.0395 ± 0.0332

Group III (Concentration of Zinc in ppm)

0.0108 ± 0.0080

1.4326   ± 0.4563

0.5971 ± 0.0922

0.3138   ± 0.0737

Group IV(Concentration of Copper in ppm)

0.0013 ± 0.0026

0.0008 ± 0.0026

0.0005 ± 0.0007

0.0004 ± 0.0005

Group IV(Concentration of Zinc in ppm)

0.0018 ± 0.0026

0.0015 ± 0.0027

0.0015 ± 0.0013

0.0005 ± 0.0001

Table 2

One way ANOVA to compare the concentration of Copper (Group I, III & IV) and Zinc (Group II, III & IV) between the three groups at 24 hrs, 7 days, 14 days & 28 days.

Concentration of copper in ppm

Concentration of zinc in ppm

Sum of Squares

df

Mean Square

F

Sig.

Sum of Squares

df

Mean Square

F

Sig.

24 hrs

Between Groups

.002

2

.001

5.001

.011

.001

2

.000

11.942

.000

Within Groups

.008

42

.000

.002

42

.000

Total

.010

44

.003

44

7th day

Between Groups

.950

2

.475

145.101

.000

71.834

2

35.917

297.983

.000

Within Groups

.138

42

.003

5.062

42

.121

Total

1.088

44

76.896

44

14th day

Between Groups

.419

2

.209

361.802

.000

6.155

2

3.077

492.514

.000

Within Groups

.024

42

.001

.262

42

.006

Total

.443

44

6.417

44

25th day

Between Groups

.141

2

.070

151.002

.000

4.413

2

2.206

346.632

.000

Within Groups

.020

42

.000

.267

42

.006

Total

.160

44

4.680

44

Table 3

Post hoc Tuckey HSD for multiple comparisons of concentration of Copper (Group I, III & IV) and Zinc (Group II, III & IV) between the three groups at 24 hrs, 7 days, 14 days & 28 days.

Concentration of copper in ppm

Concentration of zinc in ppm

Mean Difference & Standard error

Sig.

Mean Difference & Standard error

Sig.

At 24 hrs

Group I & III

0.0132 ± 0.0051

.036

Group II & III

0.0017 ± 0.0024

.753

Group I & IV

0.0147 ± 0.0051

.017

Group II & IV

0.0106 ± .0024

.000

Group III & IV

0.0015 ± 0.0051

.952

Group III & IV

0.0090 ± 0.0024

.001

At 7th day

Group I & III

0.1529 ± 0.0209

.000

Group II & III

1.6609 ± 0.1268

.000

Group I & IV

0.3549 ± 0.0209

.000

Group II & IV

3.0920 ± 0.1268

.000

Group III & IV

0.2019 ± 0.0209

.000

Group III & IV

1.4310 ± 0.1268

.000

At 14th day

Group I& III

0.1221 ± 0.0088

.000

Group II & III

0.2933 ± 0.0290

.000

Group I & IV

0.2363 ± 0.0088

.000

Group II & IV

0.8889 ±0.0289

.000

Group III & IV

0.1142 ± 0.0088

.000

Group III & IV

0.5956 ± 0.0289

.000

At 28th day

Group I & III

0.0941 ± 0.0079

.000

Group II & III

0.4497 ± 0.0291

.000

Group I & IV

0.1332 ± 0.0079

.000

Group II & IV

0.7630 ± 0.0291

.000

Group III & IV

0.0391 ± 0.0078

.000

Group III & IV

0.3133 ± 0.0291

.000

Table 4

Paired Sample T test for comparison of concentration of Copper at 24hrs, 7th day, 14th day & 28th day

Group I

Group III

Group IV

T

df

Sig. (2-tailed)

t

df

Sig. (2-tailed)

t

df

Sig. (2-tailed)

24hrs & 7th day

-22.570

14

.000

-8.858

14

.000

.529

14

.605

24hrs & 14th day

-34.248

14

.000

-15.005

14

.000

1.277

14

.222

24hrs & 28th day

-16.111

14

.000

-4.152

14

.001

1.562

14

.140

7th day & 14th day

7.662

14

.000

4.514

14

.000

.370

14

.717

7th day & 28th day

15.918

14

.000

7.300

14

.000

.569

14

.578

14th day & 28th day

14.694

14

.000

6.919

14

.000

.807

14

.433

Table 5

Paired sample t test for comparison of concentration of zinc between 24 hrs, 7th day, 14th day & 28th day

Group II

Group III

Group IV

t

Df

Sig. (2-tailed)

t

df

Sig. (2-tailed)

t

df

Sig. (2-tailed)

24 hrs & 7th day

-30.455

14

.000

-12.181

14

.000

.244

14

.811

24 hrs & 14th day

-33.791

14

.000

-25.479

14

.000

.354

14

.728

24 hrs & 28th day

-24.328

14

.000

-15.929

14

.000

1.884

14

.081

7th day & 14th day

20.280

14

.000

7.018

14

.000

.000

14

1.000

7th day & 28th day

21.539

14

.000

8.950

14

.000

1.271

14

.224

14th day & 28th day

3.654

14

.003

8.696

14

.000

2.958

14

.010

Table 6

Independent sample T test for comparison of concentration of Copper and Zinc at, 7th day, 14th day & 28th day

Group I & II

Group III

Group IV

t

df

Sig. (2-tailed)

t

df

Sig. (2-tailed)

t

df

Sig. (2-tailed)

24 hrs

-

-3.469

28

.002

-.491

28

.627

7th day

-26.880

28

.000

-10.253

28

.000

-.767

28

.450

14th day

-23.973

28

.000

-19.345

28

.000

-2.583

28

.015

28th day

-20.654

28

.000

-13.141

28

.000

-.439

28

.664

Results

The mean concentration of copper and zinc ions released into the artificial saliva from the different group of brackets during each time period is presented in Table 1 & Figure 1, Figure 2, Figure 3, Figure 4, Figure 5. The highest concentration of ion release (3.0935 ± 0.3916 ppm) (was noted in zinc at 7th day in Group II (Zinc oxide nano particles coated brackets), whereas the lowest concentration of ion release was noted for copper ions (0.0004 ± 0.0005 ppm) in uncoated brackets at 28th day (Table 1).

The amount of copper and zinc released from the coated and uncoated brackets were significantly different from each other at all the four time intervals tested except between the combination coated and uncoated brackets at 24 hrs for copper (P value = 0.952) and between the zinc coated brackets and combination coated brackets at 24hrs for Zinc (P value =0.753) (Table 1, Table 2 ). The amount of copper ions released from Group III were significantly lesser than that of from Group I brackets and greater than that of uncoated brackets at all the time intervals tested except at 24 hrs where the difference was not statistically significant (Table 1, Table 2, Table 3). Similarly the amount of zinc ions released from the Group III brackets were significantly lesser than that of Group I brackets and greater than that of uncoated brackets except at 24 hrs where the between group II & Group III values were not significant, significant (Table 1, Table 2, Table 3).

The largest quantity of Copper and Zinc release was noted on the 7th day for the both individually coated and combination brackets and from there the levels decreased significantly. At the end of 28 days the ion concentration was significantly lesser than that of the 7th & 14th day but was greater than the 24 hours value (Table 1, Table 4, Table 5) (Figure 1, Figure 2, Figure 3, Figure 4, Figure 5, Figure 6). In uncoated brackets the amount of both the ions evaluated were not significantly different between the time intervals except for zinc, where the ion levels decreased significantly from 14th day to the 28 th day (Pvalue = 0.010) (Table 1, Table 4, Table 5). The amount of Copper released was significantly less than that of Zinc at all the time intervals tested for coated brackets whereas in uncoated brackets the values were not significantly different. (Table 6)

Discussion

The quantity of the metal ions leaching into the oral cavity is a major concern in the biocompatibility of orthodontic appliances and had been evaluated extensively, yet studies related to the leaching of ions from the nanocoatings of various components of orthodontic appliance is limited. 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 20 Attempts had been made to reduce the toxicity of the metals or metal oxides used for nanocoating by using a combination method, where two different nanoparticle mixed in equal proportion by weight was used for coating substrate surfaces.12, 13 However previous studies have suggested that the amount of released metal ions is not always proportional to the content of metal in the alloy. 22, 24, 25 Hence the present study compared the amount of copper and zinc ions released from the copper oxide, zinc oxide and copper oxide –zinc oxide nanocoated orthodontic stored in the artificial saliva incubated at 37ºC at four different time intervals.

In our present study the combination nanocoated orthodontic brackets released less copper and zinc ions than that of the individually coated brackets in artificial saliva stored at 37ºC. This may be a plausible explanation for the reduced cytotoxicity of these combination brackets as reported in our previous study. 21 The greatest release of both copper and zinc ions from group I, group II & group III brackets was during the 7th day followed by a gradual decline towards the end of the study period. This kinetics of ions release cannot be due to the cumulative effect or the saturation of the artificial saliva with ions because the whole solution was changed every time after collecting the sample at the stipulated time period. 24 This pattern coincides with the pattern of release of metal ions from orthodontic appliances in artificial saliva as demonstrated in previous studies. 20, 23, 26 The gradual decline following the initial surge of ion release may be due to formation of a stable oxide layer that prevents further ion release. 23, 24, 25, 27, 26 

The quantity of copper and zinc ions measured from the samples of the present study are insignificant from a toxicological standpoint (Table 1). The mean amount of ions released from the coated brackets over the 28 days study period when projected to 20 brackets is well below the daily recommended dietary intake level of copper and Zinc. 28, 29 The recommended dietary allowance of copper is 900 μg/day for adults with an upper intake limit of 10,000 μg/day and for zinc it is 8-11 mg/ and 40 mg/day respectively. Hence a systemic toxic effect from these coated brackets is unlikely. However the ions released could cause local effects in the mucous membrane or allergic reactions. Though the antigenic potential of an allergen has to be 5 to 12 times stronger for it to cause an allergic reaction in the oral mucous membrane when compared to skin, hypersensitive reactions to components of fixed orthodontic treatment is not a rare phenomenon. 30

The quantity of zinc ions was greater than the quantity of copper ions at all-time intervals tested in coated brackets. This was similar to the finding observed in our previous study where copper oxide and zinc oxide nanocoated stainless steel brackets were evaluated. 20

The similar pattern was observed in the copper oxide –zinc oxide coated orthodontic brackets. A logical explanation could be the stability of copper oxide coating on a stainless steel substrate when compared to zinc oxide coating and should be further evaluated before arriving into concrete conclusions. Despite the fact that stainless steel brackets donot contain copper or zinc in their alloy composition, a negligible amount of copper and Zinc ions were noted in the samples collected in uncoated bracket group (Table 1 & Figure 6). The source of the ions could be from the solder or brazing material used during the manufacturing of the stainless steel bracket which contains copper and zinc. 24, 31 The quantity of the ions displayed a sharp decline with time reaching to the levels of 0.0004 ± 0.0005 ppm for copper & 0.0005 ± 0.0001 ppm for zinc at 28th day (Table 1 ).

The study was conducted under invitro conditions and cannot be directly applied to the clinical scenario, however the results of the study will be useful for relative comparison of the quantities of ions released from the different group of brackets and also to determine effect of type of coating and time on the quantity of ions released. The release of ions from the nanocoatings cannot be prevented completely. However the variables affecting the biodegradation of the coatings can be identified in future studies, so that the release of ions can be kept well within the upper limit of their biological tolerance.

Conclusion

Brackets coated with combination of copper oxide and zinc oxide nanoparticles released lesser quantity of copper and zinc ions into the artificial saliva when compared with the copper or zinc oxide nanocoated brackets . The coated brackets released more ions than uncoated brackets and the highest surge of ion release was noted at the 7th day in all the three coated groups for both ions evaluated.

Source of Funding

None.

Conflict of Interest

None.

References

1 

AR Mhaske PC Shetty NS Bhat CS Ramachandra SM Laxmikanth K Nagarahalli Antiadherent and antibacterial properties of stainless steel and NiTi orthodontic wires coated with silver against Lactobacillus acidophilus-an in vitro studyProg Orthod20151640

2 

B Cao Y Wang N Li B Liu Y Zhang Preparation of an orthodontic bracket coated with an nitrogen-doped TiO (2-x)N(y) thin film and examination of its antimicrobial performanceDent Mater J20133223117

3 

D J Aldabagh T L Alzubadi A F Alhuwaizi Tribology of Coated 316L SS by Various NanoparticlesInt J Biomater20233113

4 

HS Ryu IH Bae KG Lee HS Hwang KH Lee JT Koh Antibacterial effect of silver-platinum coating for orthodontic appliancesAngle20128211518

5 

N Mayma D Sangeetha K Ravi Evaluation of antimicrobial property of nanochitosan coated orthodontic brackets against Streptococcus mutans and Lactobacillus acidophilus - an in vitro studyAPOS Trends Orthod2023138290

6 

A G Shah P C Shetty C S Ramachandra N S Bhat S M Laxmikanth In vitro assessment of photocatalytic titanium oxide surface modified stainless steel orthodontic brackets for antiadherent and antibacterial properties against Lactobacillus acidophilusAngle Orthod201181

7 

M Kachoei F Eskandarinejad B Divband M Khatamian The effect of zinc oxide nanoparticles deposition for friction reduction on orthodontic wiresDent Res J201310505505

8 

P Salehi N Babanouri M Roein-Peikar F Zare Long-term antimicrobial assessment of orthodontic brackets coated with nitrogen-doped titanium dioxide against Streptococcus mutans.Prog Orthod201819135

9 

VM Kobbe K Doll M Stiesch A Demling Comparison of intraoral biofilm reduction on silver; coated and silver ion implanted stainless steel bracket materialJ Orofac Orthop20198013243

10 

S Leonetti B Tuvo B Campanella S Legnaioli M Onor E Bramanti Evaluation of Microbial Adhesion and Biofilm Formation on Nano-Structured and Nano-Coated Ortho-Prosthetic Materials by a Dynamic ModelInt J Environ Res Public Health20201731013

11 

RP Allaker Nanoparticles and the Control of Oral Biofilms.Nanobiomaterials Clin Dent201321320330

12 

NK Zeidan NM Enany GG Mohamed ES Marzouk The antibacterial effect of silver, zinc-oxide and combination of silver/zinc oxide nanoparticles coating of orthodontic brackets (an in vitro study)BMC Oral Health202222230

13 

B Ramazanzadeh A Jahanbin M Yaghoubi N Shahtahmassbi K Ghazvini M Shakeri Comparison of antibacterial effects of ZnO and CuO nanoparticles coated brackets against Streptococcus mutansJ Dent (Shiraz)20151632005

14 

S Duraisamy N Anandan R Kannan Evaluation of antibacterial effect of hybrid nano-coating of stainless steel orthodontic brackets on Streptococcus mutans - An in vitro studyJ Pharm Bioall Sci2023162795802

15 

A Satija MS Sidhu S Grover V Malik P Yadav R Diwakar Evaluation of salivary and serum concentration of nickel and chromium ions in orthodontic patients and their possible influence on hepatic Enzymes: an in vivo studyJ Indian Orthod Soc201448451842

16 

T Eliades H Pratsinis D Kletsas G Eliades M Makou Characterization and cytotoxicity of ions released from stainless steel and nickel-titanium orthodontic alloysAm J Orthod Dentofac Orthop200412512433

17 

M Mikulewicz K Chojnacka B Woźniak Release of Metal Ions from Orthodontic Appliances: An In Vitro StudyBiol Trace Elem Res2012146272280

18 

GM Gürsoy L Taner G Akca Nanosilver coated orthodontic brackets: in vivo antibacterial properties and ion releaseEur J Orthod2017391916

19 

N Mobeen S Kishore R Gandhi S Duraisamy K Ravi Biosafety of nanoparticles used in orthodontics: a literature reviewJ Evol Med Dent Sci20211032265865

20 

N Mobeen S Duraisamy Evaluation and comparison of copper and zinc ion release from copper-oxide and zinc- oxide nanoparticles coated orthodontic brackets - An In vitro StudyInt J Orthod Rehabil20221331021

21 

S Duraisamy N Anandan Evaluation of cytotoxicity of copper oxide and zinc oxide hybrid nanocoated orthodontic bracketsJ Contemp Orthod20248217

22 

NR Gjerdet H Hero Metal release from heat-treated orthodontic archwiresActa Odontol Scand198745640914

23 

RD Barret SE Bishara JK Quinn Biodegradation of nickel and chromium in vitroAm J Orthod Dentofac Orthop19931031814

24 

M Kuhta D Pavlin M Slaj Suzana Varga, Marina Lapter-Varga, Mladen Slaj; Type of Archwire and Level of Acidity: Effects on the Release of Metal Ions from Orthodontic AppliancesAngle Orthod200979110210

25 

CJ Hwang JS Shin JY Cha Metal release from simulated fixed orthodontic appliancesAm J Orthod Dentofac Orthop2001120438391

26 

T Eliades S Zinelis MA Papadopoulos G Eliades AE Athanasios Nickel content of as-received and retrieved NiTi and stainless steel archwires: assessing the nickel release hypothesisAngle Orthod20047421514

27 

HH Huang YH Chiu TH Lee Ion release from NiTi orthodontic wires in artificial saliva with various aciditiesBiomaterials20032420358592

28 

RB Saper R Rash Zinc: an essential micronutrientAm Fam Physician200979976872

29 

Ins Med (US) Panel Micronutients Dietary Reference Intakes for Vitamin A, Vitamin K, ArsenicProc Natl Acad Sci2001https://www.ncbi.nlm.nih.gov/books/NBK222310/?report=printable

30 

B Magnusson M Bergman BO Bergman R Söremark Nickel allergy and nickel-containing dental alloysScand J Dent Res19829016370

31 

T Eliades S Zinelis C Bourauel G Eliades Manufacturing of Orthodontic Brackets: A Review of Metallurgical Perspectives and ApplicationsRecent Patent Mat Sci2010121359



jats-html.xsl


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International, which allows others to remix, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

  • Article highlights
  • Article tables
  • Article images

Article History

Received : 12-06-2024

Accepted : 02-07-2024


View Article

PDF File   Full Text Article


Downlaod

PDF File   XML File   ePub File


Digital Object Identifier (DOI)

Article DOI

https://doi.org/10.18231/j.jco.2024.040


Article Metrics






Article Access statistics

Viewed: 292

PDF Downloaded: 79